| Practice Number | Practice | Points Available with this Product | Additional Conditions of Use to Earn Points | Manufacturer's Comments |
| 703.2.1 | Insulation and air sealing installed. | 3-15 | This product meets the requirements of 703.2.1.1.1c only. All the additional criteria of 703.2.1 must be met. 15 points awarded when all criteria are 3rd party verified. | |
| 704.6.2.1 | Bldg env. leakage rate demon. by blower door test. The following are required.: whole bldg ventilation provided; fossil fuel furnace & water heater sealed combustion/power vented; fireplaces & fuel burning appliances in accordance with Section 901.2. | 3-15 | Whole house leakage testing must be conducted by a third party to verify performance. Points awarded as follows: 3 pts if leakage is less than 5ACH50, 6 pts for <4ACH50, 9 pts for <3ACH50, 12 pts for <2ACH50, 15 pts <1ACH50 AND compliance is demonstrated to 704.6.2.1 (1)-(3). | |
| 901.11 | Formaldehyde emissions of insulation is in accordance with CDPH 01350. | 4 | Product must be used for at least 85 % of all building insulation in the building. | |
| 901.3(1)(b) | A continuous air barrier is provided between walls and ceilings separating the garage space from the conditioned living spaces. | 2 | Walls and ceiling separating the garage from the home must be fully insulated with this product and any door in the wall must be tightly sealed and gasketed. | |