| Practice Number | Practice | Points Available with this Product | Additional Conditions of Use to Earn Points | Manufacturer's Comments |
| 701.4.3.1(2) | Shafts opening to unconditioned space are sealed with blocking or flashing; gaps are sealed with caulk or foam. Mandatory for certification. | Mandatory | This product must be used to seal all shafts and gaps opening to unconditioned space. | Dramatically reduces your energy bills.
Provides a seal to help reduce pollutants and allergens.
Reduce the amount of moisture-laden air.
Decreases drafts.
Provides a first line of defence against pests.
Reduces unwanted outside noise by up to 40% . |
| 701.4.3.3(1) | Windows and doors: Caulking, gasketing, flashing tape, foam sealant, or weatherstripping forms a complete air barrier. Mandatory for certification. | Mandatory | Product must be installed per manufacturer's instructions to form a complete air barrier around all exterior windows and doors. | |
| 701.4.3.3(2) | Band & rim joists insulated & air sealed. Mandatory for certification, if applicable. | Mandatory | Product must be installed per manufacturer's instructions to seal band and rim joists. Band and rim joists must also be insulated. | |
| 701.4.3.3(3) | (a) Sill sealer is installed between foundation and sill plate; AND (b) Seal the bottom plate of exterior walls. Mandatory for certification, if applicable. | Mandatory | Product must be installed per manufacturer's instructions to seal bottom plate of exterior walls. Sill sealer must also be installed between sill plate and foundation. | |
| 704.6.2.1 | Bldg env. leakage rate demon. by blower door test. The following are required.: whole bldg ventilation provided; fossil fuel furnace & water heater sealed combustion/power vented; fireplaces & fuel burning appliances in accordance with Section 901.2. | 3 - 15 | Testing must be conducted by a third party to verify performance. Points awarded as follows: 3 pts if leakage is less than 5ACH50, 6 pts for <4ACH50, 9 pts for <3ACH50, 12 pts for <2ACH50, 15 pts <1ACH50 AND compliance is demonstrated to 704.6.2.1 (1)-(3). | |
| 901.9.2 | Interior low-VOC adhesives and sealants are used. | 5 | This product or other compliant products must be used for at least 85% of the interior adhesives and sealants. | |
| 901.3(1)(b) | A continuous air barrier is provided between walls and ceilings separating the garage space from the conditioned living spaces. | 2 | Product must be installed per manufacturer's instructions to seal all openings and form an air barrier between garage and living space. | |