Product Name: EnergyCompleteâ„¢ Spray Foam with Flexible Seal Technology
Product Manufacturer: Owens Corning

Back to previous page

Practice NumberPracticePoints Available with this ProductAdditional Conditions of Use to Earn PointsManufacturer's Comments
701.4.3.1(2)Shafts opening to unconditioned space are sealed with blocking or flashing; gaps are sealed with caulk or foam. Mandatory for certification.MandatoryThis product must be used to seal all shafts and gaps opening to unconditioned space.Dramatically reduces your energy bills. Provides a seal to help reduce pollutants and allergens. Reduce the amount of moisture-laden air. Decreases drafts. Provides a first line of defence against pests. Reduces unwanted outside noise by up to 40% .
701.4.3.3(1)Windows and doors: Caulking, gasketing, flashing tape, foam sealant, or weatherstripping forms a complete air barrier. Mandatory for certification.MandatoryProduct must be installed per manufacturer's instructions to form a complete air barrier around all exterior windows and doors. 
701.4.3.3(2)Band & rim joists insulated & air sealed. Mandatory for certification, if applicable.MandatoryProduct must be installed per manufacturer's instructions to seal band and rim joists. Band and rim joists must also be insulated. 
701.4.3.3(3)(a) Sill sealer is installed between foundation and sill plate; AND (b) Seal the bottom plate of exterior walls. Mandatory for certification, if applicable.MandatoryProduct must be installed per manufacturer's instructions to seal bottom plate of exterior walls. Sill sealer must also be installed between sill plate and foundation. 
704.6.2.1Bldg env. leakage rate demon. by blower door test. The following are required.: whole bldg ventilation provided; fossil fuel furnace & water heater sealed combustion/power vented; fireplaces & fuel burning appliances in accordance with Section 901.2.3 - 15Testing must be conducted by a third party to verify performance. Points awarded as follows: 3 pts if leakage is less than 5ACH50, 6 pts for <4ACH50, 9 pts for <3ACH50, 12 pts for <2ACH50, 15 pts <1ACH50 AND compliance is demonstrated to 704.6.2.1 (1)-(3). 
901.9.2Interior low-VOC adhesives and sealants are used.5This product or other compliant products must be used for at least 85% of the interior adhesives and sealants. 